Call us if you have any questions. Florida: 800-481-7448 Ohio: 866-476-4510


10 Gauge (minimum) is recommended for direct bury applications.
| 10 Gauge = .137” Wall Thickness | ||||
| Part No. |
I.D. |
Length |
Weight |
Wall |
| FMP 210/10 |
2.375 IN. |
10 FT. |
5.6 |
.137 |
| FMP 205/10 |
2.375 IN. |
5 FT. |
5.6 |
.137 |
| FMP 410/10 |
4.500 IN. |
10 FT. |
8.4 |
.137 |
| FMP405/10 |
4.500 IN |
5 FT. |
8.4 |
.137 |
| FMP 510/10 |
5.563 in. |
10 ft. |
10.1 |
.137 |
| FMP 505/10 |
5.563 in. |
5 ft. |
10.1 |
.137 |
| FMP 610/10 |
6.625 in. |
10 ft. |
12 |
.137 |
| FMP 605/10 |
6.625 in. |
5 ft. |
12 |
.137 |
| 7 Gauge = .188” Wall Thickness | ||||
| Part No. |
I.D. |
Length |
Weight |
Wall |
| FMP210/187 |
2.375 IN. |
10 FT. |
7.1 LBS. |
.188 IN. |
| FMP310/187 |
3.500 IN. |
10 FT. |
8.8 LBS. |
.188 IN. |
| FMP410/187 |
4.500 IN |
10 FT. |
10.8 LBS. |
.188 IN. |
| FMP510/187 |
5.563 IN. |
10 FT. |
12.8 LBS. |
.188 IN. |
| FMP610/187 |
6.625 IN. |
10 FT. |
14.9 LBS. |
.188 IN |
| 3 Gauge = .250” Wall Thickness | ||||
| Part no. | I.D. | Length | Weight | Wall |
| FMP210/250 |
2.375 IN. |
10 FT. |
8.2 LBS. |
.250 IN. |
| FMP310/250 |
3.500 IN. |
10 FT. |
11.7 LBS. |
.250 IN |
| FMP410/250 |
4.500 IN |
10 FT. |
14.5 LBS. |
.250 IN. |
| FMP510/250 |
5.563 IN. |
10 FT. |
17.3 LBS. |
.250 IN. |
| FMP610/250 |
6.625 IN. |
10 FT. |
20.2 LBS. |
.250 IN. |
| 12 Gauge and lighter wall thicknesses are popular in certain above ground applications.Shorter lengths available upon request. | ||||
| 12 Gauge = .120” Wall Thickness | ||||
| Part No. |
I.D. |
Length |
Weight lbs |
Wall |
| FMP 210/12 |
2.375 IN. |
10 FT. |
4.9 |
.120 |
| FMP 205/12 |
2.375 IN. |
5 FT. |
4.9 |
.120 |
| FMP 410/12 |
4.500 IN. |
10 FT. |
7.4 |
.120 |
| FMP405/12 |
4.500 IN |
5 FT. |
7.4 |
.120 |
| FMP 510/12 |
5.563 in. |
10 ft. |
8.8 |
.120 |
| FMP 505/12 |
5.563 in. |
5 ft. |
8.8 |
.120 |
| FMP 610/12 |
6.625 in. |
10 ft. |
10.5 |
.120 |
| FMP 605/12 |
6.625 in. |
5 ft. |
10.5 |
.120 |
| 14 Gauge = .074” Wall Thickness | ||||
| Part No. |
I.D. |
Length |
Weight lbs |
Wall |
| FMP 210/14 |
2.375 IN. |
10 FT. |
2.9 |
.074 |
| FMP 205/14 |
2.375 IN. |
5 FT. |
2.9 |
.074 |
| FMP 410/14 |
4.500 IN. |
10 FT. |
4.6 |
.074 |
| FMP405/14 |
4.500 IN |
5 FT. |
4.6 |
.074 |
| FMP 510/14 |
5.563 in. |
10 ft. |
5.4 |
.074 |
| FMP 505/14 |
5.563 in. |
5 ft. |
5.4 |
.074 |
| FMP 610/14 |
6.625 in. |
10 ft. |
6.5 |
.074 |
| FMP 605/14 |
6.625 in. |
5 ft. |
6.5 |
.074 |
| 10 Gauge = .137” Wall Thickness | |
| Part No. |
I.D. |
| FMP 210/12 |
2.375 IN. |
| FMP 205/12 |
2.375 IN. |
| FMP 410/12 |
4.500 IN. |
| FMP405/12 |
4.500 IN |
| FMP 510/12 |
5.563 in. |
| FMP 505/12 |
5.563 in. |
| FMP 610/12 |
6.625 in. |
| FMP 605/12 |
6.625 in. |
| FMP 505/14 |
5.563 in. |
| FMP 610/14 |
6.625 in. |
| FMP 605/14 |
6.625 in. |
FMP Internal Rotator Couplings each come with stainless steel fasteners. Rotator Couplers come standard in 10 Gauge Galvanized wall thicknesses. 10” and larger come standard in 3 Gauge. Larger sizes up to 30” available upon request.
| FMP Rotation Couplers | |
| Part No. |
Description |
| ICR2/10 |
2" Internal Coupling (Rotate for Sweeps) |
| ICR3/10 |
3” Internal Coupling (Rotate for Sweeps) |
| ICR4/10 |
4” Internal Coupling (Rotate for Sweeps) |
| ICR5/10 |
5” Internal Coupling (Rotate for Sweeps) |
| ICR6/10 |
6” Internal Coupling (Rotate for Sweeps) |
| ICR8/10 |
8” Internal Coupling (Rotate for Sweeps) |
| ICR8/10 |
10” Internal Coupling (Rotate for Sweeps) |
| ICR10/250 |
12” Internal Coupling (Rotate for Sweeps) |
STEEL PIPE MANUFACTURERS
Ironhed, LLC
Providence Pipe