Galloway Group
Call us if you have any questions. Florida: 800-481-7448 Ohio: 866-476-4510

PVC Pipe / Conduit

Schedule 40 Rigid PVC

Nonmetallic Conduit
(Heavy Wall EPC)

Listed for underground applications encased in concrete or direct burial. Also for use in exposed or concealed applications

above ground. • Sunlight resistant • Rated for use with 90°C conductors • Superior weathering characteristics

Schedule 40 Heavy Wall
Nom. Size Std. Crate Qty. Wt. Per Dimensions
10’ 20’ 100’ O.D. I.D. Wall
1/2” 6000’ 17 .840 .622 .109
3/4” 4400’ 8800’ 23 1.050 .824 .113
1” 3600’ 7200’ 34 1.315 1.049 .133
11/4” 3300’ 6600’ 46 1.660 1.380 .140
11/2” 2250’ 4500’ 55 1.900 1.610 .145
2” 1400’ 2800’ 73 2.375 2.067 .154
21/2” 930’ 1860’ 124 2.875 2.469 .203
3” 880’ 1760’ 163 3.500 3.068 .216
31/2” 630’ 1260’ 196 4.000 3.548 .226
4” 570’ 1140’ 232 4.500 4.026 .237
5” 380’ 760’ 315 5.563 5.047 .258
6” 260’ 520’ 409 6.625 6.065 .280

Schedule 80 Rigid PVC
Nonmetallic Conduit

(Extra Heavy Wall EPC-80)

Listed for use in above and below ground applications that are subject to physical damage.

• Sunlight resistant • Rated for use with 90°C conductors • Superior weathering characteristics

• For use in areas subject to physical damage

Schedule 80 Extra Heavy Wall
Nom. Size Std. Crate Qty. Wt. Per Dimensions
10’ 20’ 100’ O.D. I.D. Wall
1/2” 6000’ 21 .840 .546 .147
3/4” 4400’ 30 1.050 .742 .154
1” 3600’ 44 1.315 .957 .179
11/4” 3300’ 60 1.660 1.278 .191
11/2” 2250’ 3600’ 72 1.900 1.500 .200
2” 1400’ 2800’ 101 2.375 1.939 .218
21/2” 930’ 1880 154 2.875 2.323 .276
3” 880’ 1760’ 210 3.500 2.900 .300
4” 570’ 1140’ 308 4.500 3.826 .337
5” 380’ 760’ 428 5.563 4.813 .375
6” 260’ 520’ 588 6.625 5.761 4.32

Telephone Duct Type B & C

Telephone Duct Type B is designed for use in concrete encased installations. Type B duct meets the requirements of NEMA TC-10 and conforms to Bellcore CAO8546.

Telephone Duct Type B
Nom. Size Color Std. Crate Qty. Approx. Wt. per 100 ft. O.D. *Min. Wall
4” Grey 1260 100 4.350 .090
4” White 1260 100 4.350 .095
Telephone Duct Type B Heavy Wall
Nom. Size Color Std. Crate Qty. Approx. Wt. per 100 ft. O.D. *Min. Wall
4” Grey 1260 100 4.350 .100
4” White 1260 100 4.350 .100
Telephone Duct Type C
One belled end per 20’ length
Nom. Size Color Std. Crate Qty. Approx. Wt. per 100 ft. O.D. *Min. Wall
4” Grey 1260 151 4.350 .150
4” White 1260 151 4.350 .150
* Estimated min. wall to meet performance criteria

Telephone Duct Type D

White Only (Telephone Duct Type D is designed

to be used in exposed applications.)

Telephone Duct Type B
Nom. Size Color Std. Crate Qty. Approx. Wt. per 100 ft. O.D. *Min. Wall
4” Grey 1260 100 4.350 .090
4” White 1260 100 4.350 .095
Telephone Duct Type B Heavy Wall
Nom. Size Color Std. Crate Qty. Approx. Wt. per 100 ft. O.D. *Min. Wall
4” Grey 1260 100 4.350 .100
4” White 1260 100 4.350 .100
Telephone Duct Type C
One belled end per 20’ length
Nom. Size Color Std. Crate Qty. Approx. Wt. per 100 ft. O.D. *Min. Wall
4” Grey 1260 151 4.350 .150
4” White 1260 151 4.350 .150
* Estimated min. wall to meet performance criteria
Telephone Duct Type D White Only (Telephone Duct Type D is designed to be used in exposed applications.)
Telephone Duct Type D
One belled end per 20’ length
Nom. Size Part Number Std. Crate Qty. Approx. Wt. per 100 ft. O.D. *Min. Wall
4” 68615-020 (White) 1260 150 4.350 .160
* Estimated min. wall to meet performance criteria

Full Range of Bends - Everything You Need With One Call

 

bends.png